Kodak E30 Projector User Manual


 
10
KODAK EKTALITE E30/E31 OVERHEAD PROJECTORS
Fuse Replacement
1. Move the POWER SWITCH to the “OFF” position.
2. Disconnect the power cord and wait until the unit is completely cool.
3. Locate the fuse (see diagram). Use a screwdriver to remove the fuse
cover, then remove the used fuse.
4. Install a new fuse with the correct rating. Replace the fuse cover.
Lamps Fuse Rating
EYB, EHJ, EVD 250Volt 125Volt
For 36V400w T3.15A T10A
For 24V250w T3.15A T6.3A
For 82V360w T6.3A
Lens and Glass Cleaning and
Maintenance
Lens and Glass Cleaning and Maintenance
1. Clean the PROJECTION MIRROR, PROJECTION LENS, Fresnel lens
(inside), and STAGE GLASS with a clean, lint-free cloth.
Note:
Fresnel lens is on inside of TOP COVER. Turn clips to remove. When replac-
ing, make sure the “UP” label faces the STAGE GLASS side.