Kompernass KH 3900 Power Supply User Manual


 
- 9 -
Troubleshooting
Low output voltage
Possible cause and remedy:
The power inverter is overloaded. Reduce the
load until you no longer exceed the maximum
load as specified in the technical data.
The input voltage is below 11 V. Maintain the in-
put voltage of the power inverter above 11 V
to keep the output voltage constant.
Low battery voltage signal sounds
continually
Possible cause and remedy:
The battery is defective. Replace the battery.
Insufficient voltage or power supply. Check the
condition of the in vehicle receptacle and the
12 V vehicle plug and if necessary clean these.
No output power
Possible cause and remedy:
The power inverter is not fully warmed up.
Switch the power inverter on and off again until
the device attached to the power inverter is
supplied with power. Repeat this process in order
to switch the device on.
The ignition must be switched on for the in vehicle
receptacle to be supplied with power. Switch the
ignition on and/or in the position I.
The power inverter is overloaded. Reduce the
load until you no longer exceed the maximum
load as specified in the technical data.
The power inverter is overheated. Wait until the
device has cooled down. Ensure that there is
sufficient ventilation space. Make sure that the
connected load does not continually exceed the
maximum load, in order to avoid overheating
again.
The device fuse is burnt out. Consult the service
department in order to put the device back into
working condition. Make sure that the power in-
verter is connected to the power supply with the
correct polarity.
The cable fuse is burnt out. Change the cable
fuse as described in the chapter "Changing the
cable fuse".
Make sure that the power inverter is connected
to the power supply with the correct polarity.
Cleaning
Risk of potentially fatal electrical
shock:
• Never submerse the device in water or other
liquids!
• Do not allow any liquids to penetrate the
housing.
• Before every cleaning remove the power in-
verter from the vehicle receptacle/remove the
connection terminals from the automobile bat-
tery. Also remove any devices connected to
the power inverter.
Cleaning the housing:
Clean the housing surface with a slightly damp
cloth Never use petrol, solvents or cleaners since
these could damage the surface of the device!
In the event that the ventilation slots become dusty
you can clean these with a soft brush.
IB_KH3900_KOE2257_LB4_EN.qxd 21.02.2008 11:40 Uhr Seite 9