Kramer Electronics revision1 Network Router User Manual


 
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Communication Protocol 3000
14
Result codes (errors)
Syntax
No error. Command running succeeded
~DEV_ID@COMMAND PARAMETERS OKCRLF
Protocol Errors
Syntax Error (For example: Not enough parameters)
~DEV_ID@COMMAND ERR001CRLF
Command not available for this device
~DEV_ID@ ERR002CRLF
Parameter is out of range
~DEV_ID@COMMAND ERR003CRLF
Unauthorized access (running command without the matching login).
~DEV_ID@COMMAND ERR004CRLF
Security commands
Command Syntax Response
Read Security flag SECUR?
SECUR ON/OFF
Login
LOGIN AUTH PASSWORD
LOGIN AUTH RESULT
Get Login LOGIN?
LOGIN AUTH
Logout LOGOUT
LOGOUT RESULT
AUTH = USER \ ADMIN.
ON/OFF = "0" or "OFF"
"1" or "ON"
Login flow:
(Password and SECUR mode can be set from K-Config program).
1. Send SECUR? Command
2. If answer is SECUR OFF no login needed.
3. If answer is SECUR ON continue to login (step 4)
4. Send LOGIN USER, PASSWORD
5. Device will start to work normally.
6. If communication is not active for more than 5 minutes UDP socket will be closed and device will logout automatically so you will
need to LOGIN again.
7. To eliminate automatic logout you can send any command (for example Handshake) from time to time.
8. On program exit send LOGOUT (If not device will automatically logout after timeout).
Password sessions:
Login with user or admin password will open a match session, so it is possible to continue entering commands without re-login until connection will
terminate.
For Ethernet connection, sessions will be opened while socket connection is live.
For Serial or USB connection, session will live until time-out will reach.
* To reset admin password you need to factory reset all the device data.