show
Syntax:
show
Description:
To display the configuration of SMS trap event.
Argument:
None.
Possible value:
None.
Example:
GEFXL2-SW24(alarm-sms)# show
SMS Server : 192.168.1.7
Username : ABC
Password : ****************
Mobile Phone 1: 0968777777
Mobile Phone 2:
Mobile Phone 3:
Mobile Phone 4:
Mobile Phone 5:
Mobile Phone 6:
autologout
autologout
Syntax:
autologout <time>
Description:
To set up the timer of autologout.
Argument:
<time>: range 1 to 3600 seconds, 0 for autologout off, current setting is 180
seconds.
Possible value:
<time>: 0,1-3600
Example:
GEFXL2-SW24# autologout 3600
Set autologout time to 3600 seconds