Leica P5 Projector User Manual


 
10
Operation
Leica Lino 757665g en
de
en
F
I
E
P
NL
DK
S
N
FIN
J
CN
ROK
PL
HR
H
RUS
CZ
GR
LT
LV
EST
SLO
SK
m
TR
Checking the accuracy of the vertical
plumbing:
(only Lino P3, Lino P5 and Lino L2P5)
Place the Lock switch 3 in the "Unlocked" ( )
position.
Checking the upper plumbing point:
Checking the lower plumbing point:
Set up the laser on its tripod or wall mount bracket
near point A1 at a minimum distance of 1.5 m from
point B1. The horizontal laser is aligned in direction 1.
Mark the laser dots A1 and B1 with a pin.
Rotate the instrument by 180° so that it points in the
opposite direction 2 to direction 1. Adjust the instru-
ment so that the laser beam hits point A1 exactly. If
point B2 is no further than 2 mm away from point B1,
then the Leica Lino is within tolerance.
)
Should your Leica Lino be outside of the spec-
ified tolerance, please contact an authorised dealer-
ship or Leica Geosystems.
Display notices
Falling below or exceeding the permissible
temperature range:
The laser switches off and all symbols flash.
Outside of the self-levelling range:
The laser switches off and the symbol of the function
used starts to flash.
Pendulum locked:
(only Lino L360, L2P5, L2+, and L2)
The laser beam is not levelled and the Lock symbol 7
lights up.
1
B1
A1
B2
1.5 m
max. 2 mm
2
1
B1
A1
B2
1.5 m
max. 2 mm
2