Check/Verify FRU/Action
Check the following for proper installation.
Power Cord
On/Off Switch connector
On/Off Switch Power Supply connector
System Board Power Supply connectors
Microprocessor(s) connection
Reseat connectors
Check the power cord for continuity. Power Cord
Check the power-on switch for continuity. Power-on Switch
Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page
39 for the specic type for information about the Diagnostic programs.
In the following index, X can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX BIOS Test Passed
No action
000-002-XXX BIOS Timeout 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
000-024-XXX BIOS Addressing test failure 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
000-025-XXX BIOS Checksum Value error 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
000-026-XXX FLASH data error 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
000-027-XXX BIOS Conguration/Setup error 1. Run Setup
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
3. System board
000-034-XXX BIOS Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
3. Run memory test
4. System board
000-035-XXX BIOS Reset Condition detected 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
000-036-XXX BIOS Register error 1. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 560
2. System board
48 ThinkCentre Hardware Maintenance Manual