Lenovo 4105 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
018-250-XXX PCI Card Services error 1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX PCI Interface Test Passed
No action
020-0XX-XXX PCI Interface error 1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX PCI Test aborted by user
Information only Re-start the test, if necessary
020-196-XXX PCI test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
020-197-XXX PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
020-198-XXX PCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 41
2. Flash the system and re-test. See “Flash update
procedures” on page 251
3. Go to “Undetermined problems” on page 75
020-199-XXX PCI test failed, cause unknown 1. Go to “Undetermined problems” on page 75
2. Flash the system and re-test. See “Flash update
procedures” on page 251
3. Replace component under function test
020-262-XXXPCI system error 1. PCI card
2. Riser card, if installed
3. System board
025-000-XXXIDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX IDE interface failure
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
025-027-XXX IDE interface Conguration/Setup error
1. IDE signal cable
2. Flash the system. See “Flash update procedures”
on page 251
3. Reseat IDE signal cable
4. IDE device
5. System board
Chapter 9. Symptom-to-FRU Index 63