Diagnostic Error Code FRU/Action
015-034-XXX
USB port buffer
allocation failure
1. Reboot the system
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Run memory test
4. System board
015-035-XXX
USB port Reset condition detected
1. Remove USB device(s) and re-test
2. System board
015-036-XXX
USB port Register error
System board
015-040-XXX
USB port IRQ failure
1. Run setup and check for conflicts
2. Flash the system. See “Flash update
procedures” on page 214
3. System board
015-195-XXX
USB port Test aborted by user
Information only
Re-start the test, if necessary
015-196-XXX
USB port test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
015-197-XXX
USB port test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 55
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
015-198-XXX
USB port test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 55
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Go to “Undetermined problems” on page
90
015-199-XXX
USB port test failed, cause unknown
1. Go to “Undetermined problems” on page
90
2. Flash the system and re-test. See “Flash
update procedures” on page 214
3. Replace component under function test
018-000-XXX
PCI Card Test Passed
No action
018-0XX-XXX
PCI Card Failure
1. Riser card, if installed
2. System board
018-195-XXX
PCI Card Test aborted by user
1. PCI card
2. Information only
Re-start the test, if necessary