NOTE:ThetimerswitchmustbeinstalledinawallboxthathasaLoad
connection.Thematchingremoteswitchmustbeinstalledinawallbox
withaLineHotconnectionandaNeutralconnection.ANeutralwireto
thematchingremoteswitchneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consultan
electrician.
NOTE:Maximumwirelengthfromtimerswitchtoallinstalledremote
switchescannotexceed300ft(90m).
WIRING VIZIA MATCHING REMOTE SWITCH
(wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelertoremoteterminalscrewmarked"BK".
• SecondTravelerwallboxwirefromswitchtoremoteterminal
screwmarked"YL/RD"(note wire color).Thistravelerfromtheremote
mustgototheYellow/Redleadonthetimerswitch.
• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING TIMER SWITCH (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenlead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
Red lead.
• FirstTravelerLineHottoBlacklead.
• RemoveRedinsulatinglabelfromYellow/Redlead.
• SecondTravelerwallboxwire(note color as above)toYellow/Red
lead.Thistravelerfromthetimerswitchmustgototheterminalscrew
ontheremoteswitchmarked"YL/RD".
• LineNeutralwallboxwiretoWhitelead.
• ProceedtoStep5.
3-Way Wiring with Vizia
+
Matching
Remote Switch (w/LED) Application:
BK
RD
YL/RD
Additional
Neutral Wire
Matching Remote Switch
3
5
1
2
4
Timer Switch
1
2
Black
White
Red
4
Yellow/Red
Green
3
5
WH
Hot (Bla c k )
Neutral (White)
Timer SwitchMatching Remote Switch (with LED)
YL/RD
RD YL/RD
WH
BK
BK
Black
White
Line
120VAC, 60Hz
WH
Load
Green
Ground
Green
Ground
• Restorepoweratcircuitbreakerorfuse.
• Pressanytimerbuttontoturntheloadon.
If the load does not turn ON, refer to the
TROUBLESHOOTING section.
Timer Switch Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installationmaynowbecompletedby
tighteningmountingscrewsintowallbox.
Attachwallplate.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,
atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, NY 11747.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborfor
removalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtoveyears.Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
PK-93796-10-00-2A
©2009LevitonMfg.Co.,Inc.
Testing your Timer Switch prior to mounting in
wall box:
• Positionallwirestoprovideroomin
outletwallboxfordevice.
• Ensurethattheword“TOP”isfacing
upondevicestrap.
• Partiallyscrewinmountingscrewsin
wallboxmountingholes.
NOTE:Dresswireswithabendas
shownindiagraminordertorelieve
stresswhenmountingdevice.
Step 5 Step 4c
Step 6
Restore Power:
Restorepoweratcircuitbreakerorfuse.
Installation is complete.
Step 7
1.ToturntheloadONpressoneofthetimerbuttons.ThegreenLED
adjacenttothatbuttonwillilluminateandthetimerwillbeginto
countdownfortheselectedtimerperiod.
2.Toselectadifferentcountdowntimepressthebuttoncorrespondingto
thedesiredtime.TheLEDadjacenttothatbuttonwillilluminateandthe
timerwillbegincountdownfromthenewselection.
3.ToturntheloadOFFpresstheOFFbuttonorwaituntiltheselected
amountoftimehaspassed.TheLEDadjacenttoeachbuttonwill
extinguishastimepassestothenextpresetlevel.
OPERATION
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.leviton.com
CoveredbyoneormoreUS&Foreign
Patentsandpatentspending
©2009LevitonManufacturingCo.,Inc.
AllRightsIncludingTradeDressRightsReserved
•Degreeofprotectionprovided:IP20
•TypeofAction:1Q
FCC COMPLIANCE STATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubject
tofollowingtwoconditions:(1)thisdevicemaynotcauseharmful
interference,and(2)thisdevicemustacceptanyinterferencereceived,
includinginterferencethatmaycauseundesiredoperationofthedevice.
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfor
aClassBDigitalDevice,pursuanttoPart15oftheFCCRules.These
limitsaredesignedtoprovidereasonableprotectionagainstharmful
interferenceinaresidentialinstallation.Thisequipmentgenerates,uses,
andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin
accordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewill
notoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful
interferencetoradioortelevisionreception,whichcanbedetermined
byturningtheequipmentOFFandON,theuserisencouragedtotryto
correcttheinterferencebyoneormoreofthefollowingmeasures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthatto
whichthereceiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION
AnychangesormodicationsnotexpresslyapprovedbyLeviton
ManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatethe
equipment.
TROUBLESHOOTING
• IntermittentOperation
-Loadhasabadconnection.
-Wiresnotsecuredrmlytoleadsoftimerswitch
and/orremoteswitch.
• LoaddoesnotturnONandLocatorLEDdoesnotturnON
- Circuitbreakerorfusehastripped.
-Loadisburnedout.
-Neutralconnectionisnotwired.
• Remotedoesnotoperateload
-Ensurethattotalwirelengthdoesnotexceed300ft(90m).
-Ensurethataneutralwireisusedwithmatchingremoteswitches.
Timer Select Mode - You can change the time outs on your timer
without buying a new device!
ADVANCED PROGRAMMING FEATURE
• Four(4)TimerbuttonsandanOFFbutton.
• EachtimerbuttonhasanadjacentgreenLEDtoindicatethecurrent
countdowntime.
• ThegreenbottomLEDisONwhentheloadisOFFandisOFFwhen
the load is ON.
• Yourtimerswitchcanbeeasilyprogrammedtofunctionas1of4timers.
• LTB02isnotprogrammableasa12hourtimerbutcanbeprogrammedto
functionasanyoftheothertimers.
Timer Override
TooverridetheTimercountdownpressandholdthetopbuttonforseveral
seconds.ThelocatorLEDwillturnambertoindicatetheEXTENDEDON
state.InthisstatethetimerwillautomaticallyturnOFFafter24hours.Toexit
theEXTENDEDONstatepressanyofthetimerbuttonsortheOFFswitch.
Yourtimercanbeprogrammedtofunctionasanyofthetimersinthe
tablebelow:
NOTE:IfyouchangetheONtimesofyourtimertheprintedfacewillno
longermatchtheONtimes.Atimerchangekitshouldbepurchasedto
alleviate this situation.
To select different on times please follow the subsequent steps:
1. Press and hold the 1st and 3rdtimerbuttonstoenterSelectTimerMode.
2.ThecurrentactiveTimerLEDwillashgreentoindicatethedeviceisin
SelectTimerMode.
3.Pressthebutton(fromthetableabove)correspondingwiththetimeouts
you desire.
4.ThenewTimerbuttonwillbrieyashtodemonstratethetimermode
chosen.
5.PressingtheOFFbuttonwillsaveprogrammingandexitprogramming
mode.Thetimerwillalsoexitprogrammingmodeautomaticallyifno
buttonsarepressedfor3minutes.
Multi-Location Control
TheTimercanbeturnedONorOFFfromanyoftheVizia
+
®
Remote
Switchlocations.ThedefaultONtimewhenaremoteispressedtoturn
theloadONwillbethelastcountdowntimechosen.Thetimercanbe
controlledfromupto10locationsusingVizia
+
CoordinatingRemote
Switchesorupto5locationsusingVizia
+
MatchingRemoteSwitches.
NOTE: Sharinganeutralwiremaycauseimproperoperation.Connectall
timerstothesamephaseorrunaseperateneutraltoeachphase.
FEATURES OF YOUR COUNTDOWN TIMER SWITCH
Button 1 - Longest ON time
Button 2
LED indicator
lights
Locator LED
Button 3
Button 4 - Shortest ON time
OFF switch
Timer buttons
+
Timer Switch Number Buttons Time outs
LTB02 1(toptimerbutton) 15m,30m,1hr,2hr
LTB12 1(toptimerbutton) 2,4,8,12hours
LTB60 2 10,20,30,60minutes
LTB30 3 5,10,15,30minutes
LTB15 4(bottomtimerbutton) 2,5,10,15minutes
N/A 5-OFFbutton N/A