Leviton VZI06-1L Switch User Manual


 
To Program:
NOTE: Have a flashlight handy if
this dimmer controls the only light
source in the room.
1. On the dimmer only, engage the
air-gap switch by gently pulling
the bottom of the push pad until
it lifts completely out of the
frame and a click is heard and all
LED’s are OFF.
2. Press push pad back into frame
and hold push pad for 7
seconds until the locator light
and the top LED (LED 1) starts
blinking.
3. Upon releasing the push pad, the locator light will continue to
blink once per second indicating the dimmer is in Mode 1, Set
Minimum Brightness mode. To change the current Minimum
Brightness level from 1-50%, use the DIM/BRIGHT Bar. This
setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level
mode. The locator light will blink twice per second. To change
the current Set Dim-Lock level from 1-100%, use the DIM/
BRIGHT Bar. If this feature is not desired, press and hold the
lower half of the DIM/BRIGHT Bar until no LED is lit. This setting
will automatically be saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode.
The locator light will blink 3 times per second. To change the
current Fade Rate, use the DIM/BRIGHT Bar to move the LED
to the desired preset level. This setting will automatically be
saved by tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each
LED represents a preset level with LED 1 (Preset 1) located at the
top and LED 7 (Preset 7) located at the bottom. Refer to chart for
settings and defaults.
NOTE: The dimmer will exit program mode after 3 minutes of
inactivity.
Testing your Dimmer prior to mounting in
wall box:
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any
manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Dimmer
Remote (with LEDs)
YL/RD
YL/RD
RD
WH
BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Step 7
Step 5
Step 6
Gently lift bottom
of push pad out
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits
for a Class B Digital Device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment OFF and ON, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving Antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/tv technician for help.
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannotexceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler to dimmer terminal screw
marked "BK".
Second Traveler wall box wire from dimmer to remote terminal
screw marked "YL/RD" (note wire color). This traveler from the
remote must go to the terminal screw on the dimmer marked
"YL/RD".
Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch
to dimmer terminal screw marked "RD".
First Traveler Line Hot to dimmer terminal screw marked "BK".
Remove Red insulating label from terminal screw marked
"YL/RD".
Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked "YL/RD". This traveler from the dimmer
must go to the terminal screw on the remote marked "YL/RD".
Proceed to Step 5.
Restore power at circuit breaker or
fuse.
Press pad until locator light is OFF.
Lights should turn ON. If lights do not
turn ON, press the upper half of DIM/
BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
OPERATION
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way application, the lights will
turn ON at brightness set on dimmer's DIM/BRIGHT bar. The
lighting can be controlled from either the dimmer or the remote
location.
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling
the bottom of the push pad until it lifts
completely out of the frame and a click is
heard and all LED’s are OFF (refer to
Figure). This will cut power to the fixture to
replace the bulb. After servicing is
complete, push the push pad back for
normal operation.
Cleaning: Clean with a damp cloth. DO
NOT use chemical cleaners.
ADVANCED PROGRAMMING FEATURES
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights will
turn on to regardless of the previous light level at which they were
turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that
the lights will have to turn ON or OFF. Fade rates can be set to one
of 7 different settings.
3-Way Wiring with Matching Remote (w/LEDs)
Application:
BK
YL/RD
RD
B
K
YL/RD
RD
4
3
2
1
5
Additional
Neutral Wire
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Red (RD)
Matching Dimmer Remote
Dimmer
4
3
5
WH
1
2
Step 4c
TROUBLESHOOTING
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer
and/or remote.
Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
Intermittent dimmer operation
- Minimum load is under 40W.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s
Techline at
1-800-824-3005
or visit Leviton's
website at
www.leviton.com
U.S. & Foreign Patents Pending
Copyright
©
2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
DI-000-VZI06-02A
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
Position all wires to provide room
in outlet wall box for device.
Ensure that the word "TOP" is
facing up on device strap.
Partially screw in mounting screws
in wall box mounting holes.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold until lights DIM to lowest
level and LED in LED Brightness Display
starts to blink – Lights remain ON for 10
seconds and then turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar –
Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar –
Lights dim to desired level.
If you continue to hold the lower half of the
DIM/BRIGHT Bar, the lights will DIM to
minimum level and then turn OFF.
NOTE: When lights are OFF you can change
the light level that the lights will turn ON to
using the DIM/BRIGHT Bar.
If there is a power outage, when the power is
restored the lights will return to the last
setting before the power interruption.
LED
Brightness
Display
DIM/BRIGHT
Bar
Push
Pad
Locator
Light
Mode Description Range Default
1 Set Min. Brightness 1-50% 25%
2 Set Dim-Lock Level 0-100%, 0=no lock 0
3 Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
Advanced Features Summary
1
2
3
4
5
6
7
LED
Brightness
Display
* default
** LED #1 is located at the top
*** The press and hold feature for the 10 second delayed off is
disabled in this mode.
Preset LED
** Fade On Fade Off
1* 1 Approx. 1.5s from full off Approx. 3s from full on
2
*** 2 No Fade No Fade
3 3 No Fade Approx. 3s from full on
4 4 Approx. 0.5s from full off Approx. 3s from full on
5 5 Approx. 0.5s from full off Approx. 1.5s from full on
6 6 Approx. 1.5s from full off Approx. 5s from full on
7 7 Approx. 1.5s from full off Approx. 10s from full on
Fade Rate Presets