LG Electronics M4214CCBA Computer Monitor User Manual


 
Controlling Multiple Set
RS-232C
A12
Transmission / Receiving Protocol
16. Abnormal state (Command: z)
Abnormal State: Used to Read the power off status when Stand-by mode.
Transmission
Data FF: Read
Acknowledgement
0: Normal (Power on and signal exist)
1: No signal (Power on)
2: Turn the monitor off by remote control
3: Turn the monitor off by sleep time function
4: Turn the monitor off by RS-232C function
8: Turn the monitor off by off time function
9: Turn the monitor off by auto off function
17. ISM mode(Command: j p)
Used to select the afterimage preventing function.
Transmission
Data 1H: Inversion
2H: Orbiter
4H: White Wash
8H: Normal
Acknowledgement
[k][z][ ][Set ID][ ][Data][Cr]
[z][ ][Set ID][ ][OK][Data][x]
[j][p][ ][Set ID][ ][Data][Cr]
[p][ ][Set ID][ ][OK][Data][x]