Low Total Cost Of Ownership:
High-Efficiency Compressor. The rotary or scroll
compressors are both energy-efficient and rugged,
to ensure continuous operation.
Free-Cooling Option. A second cooling coil allows
the system to take advantage of colder outdoor
temperatures and bypass compressor operation.
Local And Remote
M
onitoring Panels
These units provide basic monitoring
and control for a single unit or small
groups of equipment either at the
equipment location or to a remote site.
Products include:
Liebert Universal Monitor
Liebert Controllers
Leak Detection
Liebert Liqui-tect
®
leak detection
systems alert facility personnel to
the presence of leaking fluids before
serious damage results. They provide
quick sensing and accurate reporting
of leaks below the floor, above the
ceiling or at the perimeter of a room.
Produ
cts include:
Li
ebert Liqui-tect Panel
Two Channel Direct Read
Leak Detection
Liebert Zone Leak Detection Kits
Li
ebert Point Leak Detection Sensor
Fundamental Monitoring
Liebert Nform
™
is
a c
e
n
tralized monitoring and
communications software package
that combines full-scale monitoring
with cost-effective deployment
through the use of the existing
network infrastructure.
Products include:
Liebert Nform Software
Liebert IntelliSlot Web/485
C
ar
d ADPT
Advanced Monitoring
Liebert SiteScan
®
Web offers
comprehensive, centralized
monitoring, control, data analysis
and reporting for a full-range
of computer support systems. It
provides web-based site monitoring,
alarm management and
trending/analysis for critical sites.
Products include:
Liebert SiteScan Web Software
Thir
d P
arty Monitoring
System Connectivity
The u
s
e o
f open protocols allows
you to interface Liebert units and
monitoring systems with other types
and brands of control equipment
inc
lu
d
in
g B
MS, NMS, SCADA and fire
al
arm systems.
Protocols supported:
M
odbus
BACnet
S
NMP
You will find a full-range of monitoring and control systems,
communications modules designed to interface Liebert equipment with
a variety of building management systems, plus stand-alone monitoring,
control and leak detection devices.
Free-Cooling Option
When water temperature goes below 45˚F, cooling switches over to
Free-Cooling operation. A separate chilled water source can also be
used with Air-Cooled system. Note: Special cupro-nickel free-cooling
c
o
i
l m
ust be specified when applied to open cooling tower.
3
Water Temperature Sensor
Free
Cooling
Coil
Building
Cooling
Tower
Water/
Glycol
Condenser
F
or f
ur
the
r information,
please refer to www.liebert.com
Liebert Monitoring Solutions:
When You Need To Know
Field-supplied piping