Lightolier LOT Series Power Supply User Manual


 
k
VA 1.5 - 3.5 4.2
Width (A) 36” 36”
D
epth (B) 24” 24”
Height (C) 72” 80”
Operates incandescent, magnetic and electronic ballast fluorescent, high power factor compact fluorescent, and high intensity discharge (HID) lamp types.
How to Specify:
LOT Series Uninterruptible Power Supplies LOT
Page 1 of 2 1.5 kVA - 4.2 kVA Single Phase UPS System
J
ob Inf
ormation Type:
J
ob Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Company
www
.lightolier
.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
W
e r
eser
ve the right to change details of design, materials and finish.
© 2006 Genlyte Gr
oup LLC (Lightolier Division) • B0406
Overall Characteristics
87 - 90% throughput efficiency, 85% emergency efficiency
Operating temperature range 32°F (0°C) to 104°F (40°C)
Fault current rating 42kAIC
Audible noise less than 50dB at 3 ft on “A” weighted scale
Automatic low battery voltage disconnect
Electrical
Sine Wave Output
Double conversion, no interruption
Voltage regulation ±2%
Fr
equency r
egulation - synchr
onized to utility
, free running 60 Hz, ±0.5%
Output voltage distor
tion maximum 3% THD with linear load
Load power factor capability 0.7 lead to 0.7 lag
Overload capacity 125% for 10 seconds
Input power factor correcting to 0.99
Frequency range 60Hz, ±2.5%
Input harmonic current distortion <5% THD
UL 1449, ANSI,IEEE C62, 41 surge suppression
Completely solid-state Pulse Width Modulation (PWM) inverter
Inter
nal, make befor
e br
eak maintenance by-pass
Standard, UL 924 compliant, 90 minute battery backup
UL 924 auxiliary equipment 10 and 20 minute backup available
Micr
opr
ocessor contr
ol and diagnostic system
LED
ar
ray system status panel
Fault annunciating audible alarm
Current limiting start sequence
Optional output circuit breakers (OCB) and circuit breakers with trip alarm
(OCBA)
Optional nor
mally of
f load (NOL) energizes only during power outage,
normally off load with time delay (TDT) also available
Housing
Free standing, NEMA 1 enclosure
Seismic anchoring compatible
Lockable control access panel
Applications
The solid-state Pulse Width Modulated (PWM) inverter offers enhanced load
compatibility
Provides conditioned, uninterruptible power for other types of critical loads.
Consult factory for non-lighting load applications.
LOT
SERIES
I
NPUT OUTPUT UNIT BACK-UP NOL OUTPUT # ON 2ND # OF NOL NOL # OF NOL
VOLTAGE VOLTAGE SIZE DURATION CKT BRKRS VOLTAGE CKT BRKRS VOLTAGE 2nd VOLTAGE
L
OT = Single
P
hase
Uninterruptible
P
ower
Supplies
1
.5 = 1.5 kVA
2.2 = 2.2 kVA
3.0 = 3.0 kVA
3.5 = 3.5 kVA
4.2 = 4.2 kVA
A
= 120 V
G
= 120/240V
J = 277 V
L = 120/208V
0
= None
1 = Yes
T = NOL w/ TDT
0
0X = Hardwire
01X = 1 OCB
02X = 2 OCB
03X = 3 OCB
04X = 4 OCB
:
:
20X = 20 OCB
------------------
01A = 1 OCBA
02A = 2 OCBA
03A = 3 OCBA
:
:
10A = 10 OCBA
Max. Pole
Spaces 20
0
0 = 2nd
Voltage
Hardwire or no
2nd Vo
ltage
01
02
03
:
:
19
A = 1
B = 2
C
= 3
D
= 4
E = 5
F
= 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
T = 20
Z = No NOL
1
= First
2 = Second
3 = Both
0 = No NOL
A = 1
B = 2
C
= 3
D
= 4
E = 5
F
= 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
Z = No NOL
A = 120 V
G = 120/240V
J
= 277 V
L = 120/208V
Y
= 120/277V
S = 90 min
X = 10 min
Y = 20 min
(
A)
(
B)
(
C)
Electronics/
Battery
Cabinet