Lindy 39401 Switch User Manual


 
LINDY CPU IP Access Switch User Manual
55
7.3 Troubleshooting
General Operation
Problem Solution
Erratic Operation
If the CPU IP ACCESS SWITCH is connected to a KVM
switch, make sure to power on the switch before powering
on the CPU IP ACCESS SWITCH.
Sun Systems
Problem Solution
Video display problems with
HDB15 interface systems
(e.g., Sun Blade 1000 servers)
The display resolution should be set to 1024 x 768:
Under Text Mode:
1. Go to OK mode and issue the following commands:
setenv output-device screen:r1024x768x60
reset-all
Under XWindow:
1. Open a console and issue the following command:
m64config -res 1024x768x60
2. Log out
3. Log in
Video display problems with
13W3 interface systems (e.g.,
Sun Ultra servers).
The display resolution should be set to 1024 x 768:
Under Text Mode:
1.Go to OK mode and issue the following commands:
setenv output-device screen:r1024x768x60
reset-all
Under XWindow:
1. Open a console and issue the following command:
ffbconfig -res 1024x768x60
2. Log out
3. Log in