Link electronic 812-OP/K Switch User Manual


 
812-OP/K PULSE GENERATOR
SPECIFICATIONS
PULSE OUTPUTS:
One Each as Follows:
H Drive: .......................................................................4.0Vpp
V Drive:........................................................................4.0Vpp
Width: .............................................................. Meets EIA RS-170A
Connector: ................................................................75 Ohm BNC
Impedance: ................................................................75 Ohm ±1%
Coupling: .........................................................................DC
Tilt & Overshoot: ................................................................. <0.5%
Jitter:........................................................................... <1ns
Rise Time: ................................................................ 140ns ±20ns
Amplitude Stability: .................................................................±1%
COLOR SUBCARRIER OUTPUT:
Level: .........................................................................2.0Vpp
Connector: ................................................................75 Ohm BNC
Impedance: ............................................................... 75 Ohm ±1 %
Coupling: .........................................................................AC
Frequency: ............................................................... 3.579545MHz
Jitter:............................................................................ 0.5°
Amplitude Stability: ................................................................±10%
Harmonic Distortion:.............................................................. -45dB
PHASING CONTROLS:
Horizontal Phasing: ....................................................... Infinite Window
Resolution: ............................................................. 37ns Increments
Vertical Phasing: ......................................................... Infinite Window
Resolution: .................................................... 1 line or 63.5 u
S Increments
Sub-carrier Phasing:..................................................Infinite Window (360°)
Resolution: ..............................................................0.5° Increments
REFERENCE INPUTS:
Signal Type: ........................ Horizontal Blanking .Vertical Blanking, Field Identification, CFI
ENVIRONMENTAL:
Temperature: .......................................................... 0 to 50 C ambient
Humidity:..................................................... 10% to 90% non-condensing
LINK ELECTRONICS, INC.
2137 Rust Avenue
Cape Girardeau, MO 63703
Phone: 573 334 4433
FAX: 573 334 9255