REAR PANEL
A IEC MAINS SOCKET Accepts standard 50/60 Hz AC mains voltage.
B DAISY CHAIN (If provided) The incoming AC mains voltage is paralleled via this IEC
plug and can power another unit simultaneously.
C FUSE HOLDER To remove the fuse, push and turn the fuse holder cap. A
1 to 3 Amp SLO-BLO fuse is recommended.
D CIRCUIT, CHASSIS GROUND TERMINALS Grounding terminal for both chassis and circuit. Connect
together to link circuit and chassis grounds, or remove to
help isolate ground loops.
E MAIN OUTPUT (XLR) Pin 2 hot, Pin 1&3 Ground unbalanced XLR output.
F MAIN OUTPUT (RCA) LEFT (white) and RIGHT (red) amplified outputs of
selected input,paralled output XLR Outputs.
G S/PDIF INPUT Digital input
H S/PDIF or AES SELECT SWITCH Selects between S/PDIF and AES Digital inputs
I AES INPUT Digital input (For digital source equipped with AES
outputs.
A
B
C
D
E
F
G
H
I
FUSE
CIRCUIT
CHASSIS
GROUND