METRObility Optical Systems 2152-1X-01 Network Cables User Manual


 
10 Installation Guide
Upon receiving power, the “twister” goes into normal operation mode.
Verify valid connections via the PWR LED on the front panel.
If an additional extension cord is used to connect the power supply to the
outlet, follow the guidelines below.
While one end of the AC power cord can be fitted with whatever plug is
standard for the country of operation, the end that connects to the “twister”
unit’s power supply must have a female plug that fits this type of AC
receptacle.
AC 115V (North American): Use a UL-listed and CSA-certified cord
set consisting of a minimum No. 18 AWG, type SVT or SJT three-
conductor cord (15 ft. maximum length) and a parallel blade ground-
ing-type attachment plug rated 15A, 125V.
AC 230V (USA): Use a UL-listed cord set consisting of a minimum
No. 18 AWG, type SVT three-conductor cord (15 ft. maximum
length) and a Tandem blade grounding-type attachment plug rated
15A, 250V.
240V (outside USA): Use a cord set consisting of a minimum No. 18
AWG cord and grounding-type attachment plug rated 15A, 250V.
The cord set should have the appropriate safety approvals for the
country in which the “twister” is being installed and be marked HAR.