© 2008 Honeywell International Inc.
Security & Data Collection
Honeywell Scanning & Mobility
Honeywell
90 Coles Road
Blackwood, NJ 08012
856.228.8100
www.honeywell.com
For more information:
www.honeywell.com/aidc
RoHS
2002/95/EC
IS4813 Technical Specifications
Operational
Light Source
Visible Laser Diode 650 nm
Signal Output
Digital, industrial standard
Laser Power
<0.74 mW
Mechanical
Dimensions (LxWxH)
24.7 mm x 14.6 mm x 11.9 mm (0.97” x 0.57” x 0.47”)
Weight
11 g (0.39 oz)
Termination
10 pin ZIF connector
Mounting
2 mounting holes, M1.6 mm threaded, 2 mm maximum depth
Locators
2 locating holes, 0.8 mm diameter, 1 mm depth
Electrical
Input Voltage
3.3 ± 0.2 VDC (contact a Honeywell representative for availability of 5 V units)
Operating Current
110 mA @ 3.3 VDC - typical; 120 mA @ 3.3 VDC - max
Idle Current
<30 mA @ 3.3 VDC
Laser Class
Class 2: IEC60825-1, EN60825-1
Environmental
Operating Temperature
-20°C to 50°C (-4°F to 122°F)
Storage Temperature
-40°C to 70°C (-40°F to 158°F)
Humidity
5% to 95% relative humidity, non-condensing
Shock Protection
200 G
Light Levels
Sunlight: 107,000 Lux (9,940 foot-candles); Ambient: 4842 Lux (450 foot-candles)
Scan Performance
Scan Pattern
Single scan line
Scan Speed
100 scan lines per second
Sweep Angle
54° minimum
Print Contrast
35% minimum reflectance difference
Typical Performance*
Narrow Width Depth of Field
5.2 mil 70 mm - 95 mm (2.8˝ - 3.78˝)
7.5 mil 57 mm - 171 mm (2.3˝ - 6.8˝)
10.4 mil 50 mm - 210 mm (2.0˝ - 8.3˝)
13 mil 50 mm - 254 mm (2.0˝ - 10.0˝)
19.5 mil 75 mm - 300 (3.0˝ - 11.8˝)
*Resolution: 4 mil (0.102 mm)
*Performance may be impacted by bar code
quality and environmental conditions
Note: Approval and certification from agencies such as the FDA (Food and Drug Administration) must be obtained by the manufacturer of the end equipment. The specifications required for agency approval are not obtainable until
the IS4813 engine is used in its final configuration. Therefore, it becomes the responsibility of the manufacturer who incorporates the scan engines into their product to comply with all federal laser safety regulations. The manufac-
turer must submit a Laser Product Report for the FDA in the U.S. or similar forms as required by other countries. Metrologic can assist its customers in complying with the necessary procedures.