Metrologic Instruments IS6520 Series Scanner User Manual


 
3
INSTALLATION
RS232, Light Pen (IS6520-41/MS6520-41)
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
PowerLink cable into the 10-pin socket
on Cubit. You will hear a ‘click’ when
the connection is made.
3. Connect the 9-pin female end of the
PowerLink cable to the host device.
Note: Skip to step 6 if receiving power
from the host device.
4. Plug the external power supply into the
power jack on the PowerLink cable.
Check the AC input requirements
of the power supply to make sure
the voltage matches the AC
outlet. The outlet must be
located near the equipment and
be easily accessible.
5. Connect AC power to the transformer.
6. Turn on the host device.
Plugging the scanner into a port on the host system does not
guarantee that scanned information will be communicated properly to
the host system. The scanner is shipped from the factory configured
to a set of default parameters. Please refer to the MetroSelect
Configuration Guide (MLPN 00-02407) for instructions on changing the
scanner’s configuration. In addition, please check that the scanner
and host system are using the same communication protocol.
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950,
the power source should meet applicable performance requirements for a limited power
source.