Metrologic Instruments MS2221 Scanner User Manual


 
52
SCANNER AND CABLE TERMINATIONS
CABLE CONNECTOR CONFIGURATIONS
The following cables are examples of some of the standard cables that may be shipped with the StratosS scanner.
Please keep in mind that every application is unique and the cables received with the StratosS may be custom cables that are
not shown below.
RS232 Interface Cable,
MLPN 57-57210x-N-3
Pin
Function**
1
No Connect
2 RS232 TX Output
3 RS232 RX Input
4 DTR Input
5 Power/Signal Ground
6 DSR Output
7 CTS Input
8 RTS Output
9
No Connect
9-Pin D-Type Connector
Full Speed USB Cable,
MLPN 57-57201x-N-3 or MLPN 57-57227x-N-3
Pin
Function**
1 PC+5V USB
2 Data -
3 Data +
4 Ground
Locking,
Type A
57-57227x-N-3
Non-Locking, Type A
57-57201x-N-3
IBM 46xx Cable, MLPN 57-57212x-N-3
Pin
Function**
1 Signal Ground
2 IBM A+
3 IBM B -
4
No Connect
4-Pin SDL
OCIA Cable, MLPN 57-57016x-N-3
Pin
Function**
1 Shield Ground
2 R Data
3 R Data Return
4 Clock Out
5 Signal Ground
6 OCIA Clock In Return
7 Clock Out Return
8 Clock In
9
No Connect
9-Pin D-Type Connector
** All signals are referenced from the StratosS scanner.
Specifications are subject to change without notice.