Metrologic Instruments MS3580 Scanner User Manual


 
42
SCANNER AND CABLE TERMINATIONS
Cable Connector Configurations (Host End)
“Standard” PowerLink Cable
MLPN 54-54000
x
-3 straight
Pin Function
1 Shield Ground
2 RS232 Transmit Output
3 RS232 Receive Input
4 DTR Input/Light Pen Source
5 Power/Signal Ground
6 Light Pen Data
7 CTS Input
8 RTS Output
9 +5VDC
USB Power/Communication Cable
MLPN 54-54213
x
-N-3,
54-54214
x
-N-3 or 54-54235
x
-N-3
Pin Function
1 PC +5V/V_USB
2 D-
3 D+
4 Ground
Shield Shield
Stand Alone Keyboard PowerLink
Cable
MLPN 54-54020
x
-3
Pin Function
1 PC Data
2 No Connect
3 Power Ground
4 +5VDC PC Power to KB
5 PC Clock
6 No Connect
6-Pin Male Mini-DIN Connector
9
-Pin D-T
ype
Co
nn
ector
95
61
USB Type A
Locking with Power
USB