Metrologic Instruments MS9535 Network Router User Manual


 
© 2008 Honeywell International Inc.
Security & Data Collection
Honeywell Scanning & Mobility
Honeywell
90 Coles Road
Blackwood, NJ 08012
856.228.8100
www.honeywell.com
For more information:
www.honeywell.com/aidc
RoHS
2002/95/EC
Bluetooth Access Point Technical Specifications
Operational
Visual Indicators
Flashing Blue = not connected; Steady Blue = connected
Host System Interfaces
USB, RS232, Keyboard Wedge, IBM 46XX (RS485)
Wireless Technology
Radio
2.4 to 2.4835 GHz (ISM Band) Frequency-Hopping Bluetooth v2.0
Range
Class 2: 10m (33ft) – Line of sight
Data Rate (Transmission Rate)
3 Mbit/s (2.1 Mbit/s)
Profiles
Serial Port Profile (SPP)
Security
Configurable: Mode 1, Mode 2, Mode 3
Connectivity
Point-to-Point (1 device)
Mechanical
Dimensions (LxWxH)
109 mm x 77 mm x 26 mm (4.4“ x 3.1“ x 1.0”)
Weight
75g (2.7 oz)
Termination
10-pin modular RJ45
Electrical
Input Voltage
5 VDC ± 0.25V
Operating Power
0.8 W (160 mA @ 5 V) – typical
DC Transformers
Class 2: 5.2 V @ 1 A
EMC
FCC Part 15, ICES-003, EN55022 Class B
Environmental
Operating Temperature
0°C to 40°C (32°F to 104°F)
Storage Temperature
-20°C to 60°C (-4°F to 140°F)
Humidity
5% - 95% relative humidity, non-condensing
Drop
Designed to withstand 1.5m (5’) drops
Environmental Sealing
IP54