Metrologic Instruments MS9544 Scanner User Manual


 
42
SCANNER AND CABLE TERMINATIONS
Cable Connector Configurations (Host End)
RS232 PowerLink Cable
MLPN 53-53000x-3
Pin Function
1 Shield Ground
2 RS232 Transmit Output
3 RS232 Receive Input
4 DTR Input/Light Pen Source
5 Power/Signal Ground
6
Light Pen Data
(DSR Out for -14 interfaces)
7 CTS Input
8 RTS Output
9 +5VDC
9-Pin D-Type Connector
Stand-Alone Keyboard PowerLink Cable
MLPN 53-53020x-3
Pin Function
1 PC Data
2 NC
3 Power Ground
4 +5VDC PC Power to KB
5 PC Clock
6 NC
USB Cables
MLPN 53-53213x-N-3, 53-53214x-N-3 or
53-53235x-N-3
Pin Function
1 PC +5V/V_USB
2 D-
3 D+
4 Ground
Shield Shield
Locking
Type A
Non-Locking
Type A
4
2
1
3
6 5
6-Pin Male Mini-DIN Connecto