Milan Technology CERTXFX01(SC) Switch User Manual


 
C/E-R-TX-FX-01 IN THE NETWORK
Recessed switches located on each side of the media converter are used to
configure the media converter for the network.
NOTE: Switch labels are located
AT TOP of C/E-R-TX-FX-01 media converter.
MDI/MDI-X SWITCHES
(One for each RJ-45 port - located one on each side of media
converter) Allows straight-through twisted-pair cable to be
used for crossover 100BASE-TX connections.
4-POSITION SWITCH (3rd switch not used)
Auto-negotiation (UP) Detects and adapts to line speed and
operating mode of attached device.
Full/Half-duplex (UP) Allows an attached full-duplex station to
transmit and receive simultaneously. (DOWN) Allows an
attached station to transmit and receive sequentially.
Port Select Timer (UP) Selects timer duration of eleven (11) seconds.
(DOWN) Selects timer duration of five (5) seconds.
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3
Case Dimensions 5.7" x 3.0" x 1.8" (145mm x 76mm x 46mm)
Shipping Weight 3 pounds (1.4 kilograms)
Delay 400nsec round trip
Environment Temperature: 0-50°C (32° to 122° F )
Humidity 10-90%, non condensing
Altitude 0-10,000 feet
Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (unregulated 9-24VDC, 5.5W).
TN PN Requirement Location
3507 240 volts, 50 hertz United Kingdom
3342 230 volts, 50 hertz Europe
3340 120 volts, 60 hertz USA/Canada/Mexico
3346 100 volts, 50-60 hertz Japan
3511 240 volts, 50 hertz Australia
3537 (with power cord: 3522) South Africa
Warranty Lifetime
NOTE: Media Converter Slide-in-Modules can be installed in any
installation slot, in any order.
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: Redundant Fast Ethernet
Media Converters
Part Number: C/E-R-TX-FX-01
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the C/E-R-TX-FX-01 to which this declaration refers is
in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_May 1, 1999_____
Stephen Anderson, Vice-President of Engineering Date
2 kilometers - multimode
20 kilometers - singlemode
100 meters
100 meters
MDI switch setting
PST (DOWN) switch setting
MDI switch setting
PST (UP) switch setting
SWITCH
SWITCH
Do NOT connect media
converters between hubs.
Install no more than two (2)
media converters in series.