Milan Technology HB-E-TX-8 Switch User Manual


 
LAN Master™ TX8 100BASE-TX 8-Port Hub
8
7
Optionally Cascading Two LAN Master™ TX8
Hubs
Two LAN Master TX8 hubs can be cascaded using the two
connections at the front of each hub that are labelled Port 8.
To cascade two LAN Master TX8 hubs:
1. Locate or build 100BASE-TX cable with the following
characteristics:
803.2 compliant (See page 15)
cable length less than 5 meters
male RJ-45 plug connectors installed at both ends of cable.
2. Connect male RJ-45 plug connector at one end of 100BASE-TX
cable to Port 8 connector marked MDI-X.
3. Connect male RJ-45 plug connector at other end of 100BASE-
TX cable to Port 8 connector marked MDI.
Up to 5 meters
Connecting 100BASE-TX Cable
To connect 100BASE-TX Cable to LAN Master TX8 RJ-45
connectors:
1. Locate or build 100BASE-TX cables with the following
characteristics:
803.2 compliant (See page 15)
cable length less than 100 meters
male RJ-45 plug connectors installed at both ends of
cable.
2. Connect male RJ-45 plug connector at one end of 100BASE-
TX cable to LAN Master TX8 RJ-45 jack connector.
3. Connect male RJ-45 plug connector at other end of 100BASE-
TX cable to terminal device RJ-45 jack connector.
Up to 100 meters
Up to 100 meters
Up to 5 meters