Milan Technology MIL-S2400 Switch User Manual


 
Rack-mounted Installation
The MIL-S2400 and MIL-S1600 switches includes a rack-mounted kit and can be mount in an EIA
standard size, 19-inch Rack, enabling the switch to be placed in a wiring closet with other equipment.
Perform the following steps to rack mount the switch:
A. Position one bracket to align with the holes on one side of the switch and secure it with the
smaller bracket screws. Then attach the remaining bracket to the other side of the switch.
Figure 2-4. Attach mounting brackets with screws
B. After attaching both mounting brackets, position the MIL-S2400 and MIL-S1600 Switches in
the rack by lining up the holes in the brackets with the appropriate holes on the rack. Secure
the switch to the rack with a screwdriver and the rack-mounting screws.
Figure 2-5. Mount the MIL-S1600 Switch in an EIA standard 19-inch Rack
Note: For proper ventilation, allow about at least 4 inches ( 10 cm ) of clearance on the front and 3.4
inches ( 8 cm ) on the back of the switch. This is especially important for enclosed rack installation.
Power On
Connect the power cord to the power socket on the rear panel of the switch. Connect the other end of
the power cord to the power outlet. The internal power supply of the switch works with AC in the voltage
range 100-240VAC, frequency 50~60Hz.
Check the power indicator on the front panel to see if power is properly supplied.