5
TYPICAL RUN TIME vs. TYPICAL COMPUTER LOAD
Computer
Load
A300 A425 A500 A750 A900 A1250 A2000
100VA 30m 38m 68m 86m 122m 133m 379m
150VA 19m 22m 38m 48m 72m 79m 211m
200VA 12m 15m 25m 32m 50m 54m 139m
250VA 8m 11m 19m 24m 37m 41m 101m
300VA 5m 8m 14m 18m 29m 32m 78m
425VA --- 5m 9m 11m 19m 20m 47m
500VA --- --- 6m 9m 15m 16m 37m
600VA --- --- --- 7m 12m 13m 28m
700VA --- --- --- 6m 10m 11m 23m
750VA --- --- --- 5m 9m 10m 21m
800VA --- --- --- --- 8m 9m 19m
900VA --- --- --- --- 7m 8m 16m
1000VA --- --- --- --- --- 7m 14m
1100VA --- --- --- --- --- 6m 12m
1250VA --- --- --- --- --- 5m 10m
1400VA --- --- --- --- --- --- 8m
1600VA --- --- --- --- --- --- 7m
1800VA --- --- --- --- --- --- 6m
2000VA --- --- --- --- --- --- 5m
PHYSICAL SPECIFICATIONS
Model
Net Wt.
(lbs.)
Shipping Wt.
(lbs.)
Dimensions
(L x W x H) (inches)
A300 15 18 13.5 x 3.3 x 6
A425 15 18 13.5 x 3.3 x 6
A500 23 25 13 x 4.6 x 6.6
A750 29 30 16 x 4.6 x 6.6
A900 46.5 49.6 18.4 x 6.3 x 9.8
A1250 49.2 52.3 18.4 x 6.3 x 9.8