Mitsubishi Electronics XL1XU Projector User Manual


 
EN 24
Indicators
The projector has three LED Indicators which shows the working condition of the projector.
The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your
dealer.
Normal condition
Abnormal condition
Steady
red
Steady
green
Steady
green
Blinking
green
Steady
green
POWER LAMP TEMP
CONDITION Notes
The POWER is ON. (Normal condition)
Lamp stand-by (about for 1 minute) The power button cannot be used to switch
ON and OFF
Stand-by
OffOff
Off
Off
Steady
green
Blinking
green/red
Blinking
green/red
Blinking
green/red
Steady
red
Steady
green
Steady
green
Blinking
red
Blinking
red
POWER LAMP TEMP
CONDITION POSSIBLE SOLUTIONS
Steady
red
Blinking
red
Steady
red
Close the cover correctly.
or or
Blinking Blinking
Abnormal. Contact your dealer.
Off
Off
Steady
red
Blinking
green
Off
Off
Off
OffOff
Steady
red
Steady
Steady
Unusual temperature
The ventilation slits or air filter is clogged with
dust or debris.
The room temperature is too high.
The filter is dirty.
Remove the object from the ventilation
slits.
Relocate the projector to a cooler place.
Clean the filter.
Replace the lamp.
Exchange with a new lamp if the same
problem recurs.
Wait until the LAMP indicator is turned
off, then press the POWER button.
If the above operation is not effective,
replace the lamp.
The lamp cover is not closed.
The protection circuit is working or the lamp is in an
abnormal condition.
(The indicators operate as shown on the left at the time of
power-off, too. In this case, they arent indicating an
abnormal condision.)
The lamp operation time exceeds the time elapsed until the
lamp shutdown notice. (See page 21.) The POWER is on.
The lamp operation time exceeds the time elapsed until the
lamp shutdown notice. (See page 21.) The POWER is off.
The lamp operation time exceeds the time elapsed until the
lamp shutdown. (See page 21.)
LAMP indicator
POWER indicator
TEMP indicator
TEMP
LAMP
VOLUME SOURCE
COMPUTER
VIDEO
AUTO
POSITION
MENU ENTER
MUTE