Grounding Moxa EtherDevice Switch
Grounding and wire routing help limit the effects
of noise due to electromagnetic interference
(EMI). Run the ground connection from the right
most of 3-contact terminal block to the grounding
surface prior to connecting devices.
This product is intended to be mounted to a well-grounded
mounting surface such as a metal panel.
Wiring the Power Inputs
The two left-most contacts of the 3-contact terminal block connector on EDS’s
top panel are used for EDS’s DC or AC inputs. Top and front views of one of
the terminal block connectors are shown here.
STEP 1: Insert the negative/positive DC wires
into the V-/V+ terminals.
STEP 2: To keep the DC wires from pulling
loose, use a small flat-blade screwdriver to
tighten the wire-clamp screws on the front of
the terminal block connector.
STEP 3: Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is located on EDS’s top
panel.
y Only connect to a class 2 power supply.
y Use 60/75°C copper (CU) wire 28-12 AWG only.
y Use a maximum torque of 4.5 in-lb.