Wiring the Power Inputs
The two left-most contacts of the 3-contact terminal block connector on
EDS-208’s top panel are used for both the DC and AC inputs of EDS-208. Top
and front views of one of the terminal block connectors are shown here.
STEP 1: Insert the negative/positive DC or AC
wires into the V-/V+ terminals.
STEP 2: To keep the DC or AC wires from
pulling loose, use a small flat-blade screwdriver
to tighten the wire-clamp screws on the front of
the terminal block connector.
STEP 3: Insert the plastic terminal block
connector prongs into the terminal block receptor,
which is located on EDS’s top panel.
ATTENTION
y Only connect to a class 2 power supply.
y Use 60/75°C copper (CU) wire 28-12 AWG only.
y Use a maximum torque of 4.5 in-lb.
Communication Connections
EDS-208 has 7 or 8 10/100BaseT(X) Ethernet ports, and 1 or 0 (zero)
100BaseFX (SC/ST-type connector) multi-mode fiber ports.
10/100BaseT(X) Ethernet Port Connection
The 10/100BaseT(X) ports located on EDS-208’s front panel are used to
connect to Ethernet-enabled devices.
Below we show pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports, and also show cable wiring diagrams for
straight-through and cross-over Ethernet cables.
RJ45 (8-pin, MDI) Port Pinouts RJ45 (8-pin, MDI-X) Port Pinouts
RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring