Moxa Technologies EDS-308 Switch User Manual


 
15
Power
Input Voltage 12 to 48 VDC, redundant inputs
Input Current @ 24VDC 0.25 A (EDS-305, EDS-305-M, EDS-305-S, EDS-308)
0.35 A (EDS-308-M, EDS-308-S, EDS-308-MM, EDS-308-SS)
Connection Removable Terminal Block
Overload Current Protection 1.1 A (EDS-305, EDS-305-M, EDS-305-S, EDS-308) 1.6 A
(EDS-308-M, EDS-308-S, EDS-308-MM, EDS-308-SS)
Reverse Polarity Protection Present
Mechanical
Casing IP30 protection, aluminum case
Dimensions 53.6 x 135 x 105 mm (W x H x D)
Weight 0.63 kg
Installation DIN-Rail, Wall Mounting
Environmental
Operating Temperature 0 to 60oC (32 to 140oF)
-40 to 75oC (-40 to 167oF), for “-T” models
Storage Temperature -40 to 85oC (-40 to 185oF)
Ambient Relative Humidity 5 to 95% (non-condensing)
Regulatory Approvals
Safety UL60950, UL 508, CSA C22.2 No. 60950, EN60950
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C and D
ATEX Class I, Zone 2, EEx nC IIC
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
Shock IEC 60068-2-27
Free Fall IEC 60068-2-32
Vibration IEC 60068-2-6
WARRANTY
5 years