Multitech MT5634ZBA-SERIES Modem User Manual


 
Chapter 6 – Callback Security
Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide (S000286G) 20
Setting Callback Security Message Parity
The modem’s parity must match the parity of the computer to which the modem is connected.
1. Open a data communications program such as HyperTerminal or PhoneTools.
2. In the terminal window, type AT#Sxxxxxxxx, where xxxxxxxx is your password. Press E
NTER. The modem
responds with OK if the setup password is correct and ERROR if it is wrong.
3. The modem’s parity default value is No parity (AT#CBP0). To change the modem’s default to use even parity,
type AT#CBP2. Press E
NTER. For odd parity, type AT#CBP1. Press ENTER.
4. To store the new parity value, type AT&W. Press E
NTER.
Assigning Callback Passwords and Phone
Numbers
1. Open a data communications program such as HyperTerminal or PhoneTools.
2. In the terminal window, type AT#Sxxxxxxxx, where xxxxxxxx is your password. Press E
NTER. The modem
responds with OK if the setup password is correct and ERROR if it is wrong.
3. Enable callback security by typing AT#CBS1 or AT#CBS2 and pressing E
NTER.
4. To store a callback password for the first callback memory location, type AT#CBN0=xxxxxxxx, where xxxxxxxx
is the first password. Press E
NTER. The password must be unique, must be six to eight characters in length, and
must not contain a + or - character. The callback password is case sensitive.
5. To store a callback password for the second callback memory location, type AT#CBN1=xxxxxxxx, where
xxxxxxxx is the second password. Press E
NTER. Note that the memory location number in the command is
incremented by one.
6. Repeat as many times as necessary, up to memory location 29, until all passwords are entered.
7. To store a callback phone number in the first memory location, type AT&Z0=[+][-]AT(DT or DP)xxxxxxxx[,???],
where xxxxxxxx is the dialing string. Press E
NTER. The phone number must be preceded by DT for tone dialing
or DP for pulse dialing. The dialing string can also include other AT commands.
Example: AT&Z0=+-ATM0DT5551212. Up to 35 characters can be used. The +, -, and ??? characters are
optional:
+ Number entry. Enables a mobile caller to enter his current phone number for callback.
- Direct connection. Enables a caller to choose direct connection without being called back.
,??? Extension entry. Must be used with the + command. Enables a caller to enter an extension number for
callback. The number of ? characters must equal the number of digits in the extension.
8. To store a callback phone number in the second memory location, type AT&Z1=[+][-]AT(Dt or
DP)xxxxxxxx[,???], where xxxxxxxx is the dialing string, and press E
NTER. Note that the memory location
number in the command is incremented by one.
9. Repeat, through memory location 29, until all dialing strings are entered.
10. To review your entries, type AT&V and press E
NTER.
Note: A form is provided on the last page of this chapter to help you plan or keep track of password and phone
number assignments.
Calling Procedures
Use the following procedures to call a modem that has callback security enabled. Note that Autoanswer must be enabled
on the calling modem (S0=1).
Password-Only Callback
Use this procedure when calling from a fixed location.
1. Using a data communications program such as HyperTerminal or PhoneTools, dial the number of the
callback modem.
2. When the connection is established, the callback modem responds with the following message:
Password>
3. Type the password corresponding to the phone number for your modem. Press E
NTER. You have three
attempts or one minute to enter a valid password.
4. If the password is valid, the following message appears, and the modems disconnect:
OK Disconnecting