Multi-Tech Systems MT5600SMI-PL92 Modem User Manual


 
Chapter 5 – AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide 31
Command: \N Operating Mode - Error Correction
Description: Controls the preferred error-correcting mode to be negotiated in a
subsequent data connection. This command is affected by the OEM
firmware configuration.
Default: 5
Defined Values: \N0 Selects normal speed buffered mode (disables error-correction
mode). (Forces &Q6.)
\N1 Serial interface selected: Selects direct mode and is equivalent to
&M0, Q0 mode of operation. (Forces &Q0.) Parallel interface
selected: Same as \N0.
\N2 Selects reliable (error-correction) mode. The modem will first attempt
a LAPM connection and then an MNP connection. Failure to make a
reliable connection results in the modem hanging up. (Forces &Q5,
S36=4, and S48=7.)
\N3 Selects auto-reliable mode. This operates the same as \N2 except
failure to make a reliable connection results in the modem falling
back to the speed buffered normal mode. (Forces &Q5, S36=7, and
S48=7.)
\N4 Selects LAPM error-correction mode. Failure to make an LAPM
error-correction connection results in the modem hanging up.
(Forces &Q5 and S48=0.) Note: The -K1 command can override the
\N4 command.
\N5 Selects MNP error-correction mode. Failure to make an MNP error-
correction connection results in the modem hanging up. (Forces
&Q5, S36=4, and S48=128.)
Result Codes: OK
Otherwise ERROR
Command I Identification
Description: Causes the modem to reports the requested result according to the
command parameter.
Default: 4
Defined Values: I0 Reports product code (e.g., 56000).
I1 Reports the least significant byte of the stored checksum (e.g.,
12AB).
I2 Checks ROM and verifies the checksum. Reports OK or ERROR.
I3 Reports ROM Code Revision-Modulation (e.g., 2109-V90).
I4 Reports OEM defined identifier string in binary format (default) or
ASCII formats. (e.g.: a007040284C6002F bC60000000
r1005111151012000 3000111170000000).
I5 Reports Country Code parameter (see +GCI).
I6 Reports modem data pump model and internal code revision.
Result Codes: OK
Otherwise ERROR
Command: +GMI Request Manufacturer Identification
Description: Causes the modem to report the modem product manufacturer.
Typical Response: +GMI: Multi-Tech
OK