Murphy LS200 Switch User Manual


 
Application Data
Table 3
Pipe Data
Nom. Size
(inches)
O.D.
(inches)
Schedule
Number
Wall Thickness
(inches)
Inside Diameter
(inches)
3 3.5 40ST 0.216 3.068
3 3.5 80XS 0.3 2.9
4 4.5 40ST 0.237 4.026
4 4.5 80XS 0.337 3.826
Table 4
Minimum Clearance
Product Name Insertion Depth (inches) Vertical Clearance (inches)
Std. w/ 1” Extension Std. w/ 1” Extension
LS 200 4.6 5.6 2.8 3.15
LS 200N 5.43 6.4 3.3 3.9
L 1200 4.65 5.7 3.9 4.55
L 1200N 5.6 6.7 5.3 6.9
L 1100 4.4 5.4 3.4 4.05
LS200N, LS200NDVO and LS200NDVOR with Dump Valve Operator, Pressure Regulator & Gage
CAUTION: LS200 Series parts are not interchangeable with the L1200 Series.