FW Murphy – MeCAN MEC300 installation instructions 00-02-0665 28
th
November 2008 p3/3
Operation
MeCAN begins transmitting J1939 CANbus data immediately
after power-up. Data can be viewed using a J1939 compatible
display, e.g. the Murphy PV101, or used as part of a J1939
control system, e.g. Murphy CANstart or CASCADE modules.
Engine oil pressure and coolant temperature
Model 79.70.0014 transmits pressure and temperature data
when the sender input is within normal resistance range.
MeCAN also transmits appropriate SPN (Suspect Parameter
Number) and FMI (Fault Mode Indicator) codes if:
• input resistance is out of normal sender range, e.g. open-
or short-circuit
• oil pressure drops below 20 psi (warning message) and
10 psi (shutdown/derate message)
• coolant temperature rises above 90°C/194°F (warning
message) or 110°C/230°F (shutdown message)
Model 79.70.0020 transmits pressure and temperature data in
accordance with the switch position:
Input switch
closed (to –DC)
Input switch
open
oil pressure data 0 psi &
SPN/FMI code
100 psi
coolant temp data 105°C / 221°F &
SPN/FMI code
90°C / 194°F
Oil pressure fault codes are not transmitted until 10 seconds
after engine starting (once speed has risen above 800 RPM).
Engine speed data
RPM data is transmitted whenever a speed signal is present
(above the minimum 10VAC peak). If engine speed exceeds
3500 RPM, MeCAN also transmits the appropriate overspeed
fault SPN and FMI codes.
Battery voltage
MeCAN measures its DC power supply voltage and transmits
this as J1939 ‘electrical potential’ data (PGN 65271).
Hours run
MeCAN transmits ‘engine hours run’ data (PGN 65253).
The hours run value is stored in non-volatile flash memory
and increases only while engine speed is above 500 RPM.
To prolong flash memory life, hours run data is updated at
3 minute intervals.
Maintenance and Warranty
MeCAN contains no user-serviceable parts. Maintenance is
therefore limited to the following preventative checks:
• Check that MeCAN electrical connections are secure.
• Check that the case is mounted securely, with vibration
and environmental exposure minimised where possible.
The case may be wiped with a clean, damp cloth. Do not
use cleaning solvents.
MeCAN is supplied with a two year warranty on parts and
workmanship. In the event of a fault or technical query,
and before returning equipment, please contact your
Murphy representative for technical support.
OPERATION AND MAINTENANCE
FW MURPHY
P.O.Box 470248, Tulsa, Oklahoma 74147 USA
+1 918 317 4100 Fax: +1 918 317 4266
E-mail: sales@fwmurphy.com
INDUSTRIAL PANEL DIVISION
Fax: +1 918 317 4124
E-mail: ipdsales@fwmurphy.com
MURPHY POWER IGNITION
Website: www.murphy-pi.com
CONTROL SYSTEMS AND SERVICES DIVISION
P.O.Box 1819, Rosenberg, Texas 77471 USA
Phone: +1 281 633 4500 Fax: +1 281 633 4588
E-mail: sales@fwmurphy.com
FRANK W. MURPHY LTD.
Church Rd, Laverstock,
Salisbury, SP1 1QZ, United Kingdom
Tel: +44 1722 410055
Fax: +44 1722 410088
E-mail: sales@fwmurphy.co.uk
Web: www.fwmurphy.co.uk
COMPUTRONIC CONTROLS
41 – 43 Railway Terrace, Nechells,
Birmingham, B7 5NG, United Kingdom
Tel: +44 121 327 8500
Fax: +44 121 327 8501
E-mail: sales@computroniccontrols.com
Web: www.computroniccontrols.com
FW MURPHY INTERNATIONAL TRADING (SHANGHAI) CO. LTD.
Suite 1704, Tower B, City Centre of Shanghai; 100 Zunyi Road,
Shanghai, 200051 China
Phone: +86 21 6237 2082 Fax: +86 21 6237 2083
E-mail: mhong@fwmurphy.com
FW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD.
77 23
rd
Street, Hangzhou Economic & Technological Development Area
Hangzhou, Zhejiang 310018 China
Phone: +86 571 8788 6060 Fax: +86 571 8684 8878
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
MURPHY, the Murphy logo, are registered and/or common law trademarks of Murphy Industries, Inc. This document, including
textual matter and illustrations, is copyright protected by Frank W Murphy Ltd., with all rights reserved. © 2008 Frank W Murphy Ltd.