Murphy PVA20 Network Card User Manual


 
Description
The PowerView Analog Gages (PVA) are a series of intelligent gages
designed to display easy-to-read information transmitted by the PowerView.
The PVA gages communicate with the PowerView via a single RS485 twist-
ed pair MODBUS
®†
RTU serial link. The gages can be daisy-chained using
quick-connect harnesses with watertight connectors.
The PVA gages also include features such as a smooth stepper motor opera-
tion for the 270° sweep pointer, an environmentally sealed case with two
Deutsch DT style connectors molded into the casing, and green LED back
lighting. They are available for standard 2-1/16 in. (52 mm) and 3-3/8 in. (86
mm) diameter hole sizes. In addition their plastic cases incorporate a “D”
shape allowing panel cutouts that eliminate gage rotation during installation.
The PowerView Audible Alarm (PVAA) alerts operators to fault conditions
via piezoelectric alarm and relay contacts. It also has a temporary silencer
button that silences the audible tone for 2 minutes on alarms and 30 seconds
on shutdown conditions.
All PowerView Gages can be powered by 12 or 24 VDC systems.
PVA20 Series Models: 2 inch size gages:
PVA20 –A = Engine Oil Pressure
PVA20 –B = Coolant Temperature
PVA20 –C = Voltmeter
PVA20 –D = Percent Load at Current RPM
PVA20 –E = Transmission Oil Pressure
PVA20 –F = Transmission Oil Temperature
PVA20 –G = Engine Oil Temperature
PVA20 –T = Tachometer
PVAA20 = 2 inch dial audible alarm gage
PVA35 Series Models: 3-1/2 in. size gages:
PVA35 –T = Tachometer
PVA35 –S = Speedometer
Specifications
Power Supply Input Voltage: 12/24V (8-32VDC min. & max. voltage).
Power Supply Operating Current: (@ 14 VDC) =
PVA20, PVA35: 28 mA minimum; 52 mA maximum.
PVAA20: 19 mA minimum; 46 mA maximum.
Backlight Maximum Current (not applicable to PVAA20): 24 mA.
Input: RS485 MODBUS
®
RTU data.
Output: Analog Readout.
Relay Rated Load (PVAA20): 0.5 A, 125 VAC; 1 A, 24 VDC.
Relay Maximum Switching Capacity (PVAA20): 62.5 VA, 30W.
External Audible Alarm Output (PVAA20): 28 VDC, 30 mA max. (cur-
rent sink).
Temporary Silence Button (PVAA20): Charge transfer technology.
Operating Temperature: -40° to 185°F (-40° to 85°C).
Storage Temperature: -76° to 185°F (-60° to 85°C).
Dial: White numerals over black background.
Indicating Pointer: Stepper motor operation with 270° sweep.
Gage Accuracy: PVA20: Better than ±1.0% of scale.
PVA35: Better than ±2% of scale.
Environmentally Sealed Enclosure:
Sealing: IP68, ±5 psi (±34.4 kPA).
Case and Clamp Material: Polyester (PBT).
Lens Material: Polycarbonate.
Bezel Material: Polyester (PBT).
Maximum Panel Thickness: 3/8 in. (9.6 mm).
Connectors: 6-Pin Deutsch DT06 Series.
MurphyLink is a registered trademark of FWMurphy. All other trademarks and
service marks used in this document are the property of their respective owners.
CAUTION: These instruments are designed to be used ONLY
with the MurphyLink
TM
PowerView module or other approved
MurphyLink
TM
PowerView products.
Analog Gages PVA20
& PVA35 Installation Instructions
PVA-02126N
Revised 01-04
Section 78
00-02-0532
Please read the following information before installing. A visual inspection of this product for damage during ship-
ping is recommended before mounting. It is your responsibility to have a qualified person install this unit.
GENERAL INFORMATION
W
ARNING
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
Disconnect all electrical power to the machine.
Make sure the machine cannot operate during installation.
Follow all safety warnings of the machine manufacturer.
Read and follow all installation instructions.
PVA20 Series
PVA35 Series
PVA-02126N page 1 of 4