Murphy PVM Series Switch User Manual


 
Warranty
- A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty
may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
Specifications
PV101 Compatibility
Maximum supported: 5 PVM Gages
Maximum distance to last gage: 8.5 Meters
Power Supply Input Voltage
5V (4.5-5,.5.5 VDC minimum & maximum voltage)
Power Supply Operating Current (@ 5 VDC) =
PVM20, PVM35: 18 mA minimum; 80 mA maximum
Backlight Maximum Current: 60mA
Input: RS485 MODBUS® RTU data.
Output: Analog Readout.
Environmental
Operating Temperature: -40 to 185°F (-40° to 85°C)
Storage Temperature: -67 to 185°F (-55° to 85°C)
Environmental Sealed Enclosure:
Sealing: IP68, ±5 PSI (± 34.4 kPa)
Case and Clamp Material: Polyester (PBT)
Lens Material: Polycarbonate
Bezel Material: Polyester (PBT)
Dial: White numerals over black background
Return-To-Zero Needle Movement: Not Available for PVM20
models.
Indicating Pointer: Stepper motor operation with 270° sweep
Gage Accuracy: Better than ± 1.0% of scale
Maximum Panel Thickness: 3/8 inch (9.6 mm)
Connectors:
Amp Mini Universal Mate-N-Lok
Amp Plug P/N: 172338-1
Amp Socket P/N: 171639-1
Shipping Weight: 1 Lb. (450 g.)
Shipping Dimensions:
6 x 6 x 6 in. (153 x 153 x 153 mm)
Typical Gage Dimensions