Murphy XM500 Network Card User Manual


 
Warranty
- A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty
may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
Specifications
Power Input: 8 to 32 VDC
Operating Temperature: -40 to 85°C (-40° to 185°F)
Digital Inputs: 4 – Ground or battery positive activation
Digital Outputs: 2 – Sinking (500 mA)
Thermocouple Input
1
: Type K
Analog Inputs
2
:
1 – battery supply voltage (dedicated)
7 – configurable as 0-5 VDC, 4-20 mA, or Murphy resistive
sender
3
Speed Sensing input: 2 to 120 VAC RMS from 30 to 10,000 Hz.
Communication Ports: CAN J1939
LED Indicators:
PWR - Power On
COP - Computer Operating Properly
CAN - CANbus Active
Product Weight: 10 ounces
Shipping Weight: 12 ounces
Shipping Dimensions: 4” x 6” x 2”
1
When the thermocouple input is used, only 5 resistive, 4-20 mA, or 0-5 VDC, can be used instead of 7.
2
Analog inputs can be exchanged for digital inputs (battery ground activation only), for a total of ten digital inputs.
3
Other resistive senders can be supported. Contact FW Murphy’s Industrial Panel Division for programming charges.
Dimensions
How to Order
Model: XM500
Contact FW Murphy’s Industrial Panel Division for your custom application. Minimum order quantities apply.
Phone: 918 317 4100
E-mail: ipdsales@fwmurphy.com