National Instruments 9211A Computer Drive User Manual


 
© National Instruments Corporation 15 USB-9211/9211A User Guide and Specifications
Cold-junction compensation sensor accuracy
0 to 60 °C........................................0.6 °C (1.1 °F) typ,
1.3 °C (2.3 °F) max
Conversion time.....................................70 ms per channel;
420 ms total for all channels
including the autozero and
cold-junction channels
Max sampling rate (Hz)
Input bandwidth (–3 dB)........................ 15 Hz
Noise rejection ....................................... 85 dB min at 50/60 Hz
Overvoltage protection........................... ±30 V between any input and
common
Differential input impedance ................. 20 M
Input current........................................... 50 nA
Input noise.............................................. 1 µV
rms
Gain error ............................................... 0.05% max at 25 °C,
0.06% typ (over temperature)
0.1% max (over temperature)
Offset error (with autozeroing) .............. 15 µV typ, 20 µV max
Gain error from source impedance......... 0.05 ppm per source impedance
due to input impedance
Number of
Channels in
Scan List
Type of Measurement
Tempertaure
with CJC and
Autozero
Temperature
with Autozero
RAW
Analog
Input
1 4 6 12
2 3 4 6
3 2.4 3 4
4 2 2.4 3
Note: DAQmx Base always applies autozero.