National Instruments MXI Series Network Card User Manual


 
Appendix A Specifications
NI ExpressCard MXI Series User Manual A-6 ni.com
Environment
1
Maximum altitude...................................2,000 m (at 25 °C ambient
temperature)
Pollution Degree.....................................2
Indoor use only
Operating Environment
Module ambient temperature range........0 to 65 °C (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2.)
Operating relative humidity....................5 to 95%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range ....................–20 to 65 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2.)
Nonoperating thermal shock...................–20 to 65 °C, 5 shocks
Shock and Vibration
Nonoperating shock................................50 g, 11 ms (Tested in accordance
with IEC 60068-2-27.)
Nonoperating vibration,
sinusoidal................................................15 g 100 to 2000 Hz (Tested in
accordance with IEC 60068-2-6.)
Nonoperating drop test ...........................2 drops in 3 mutually exclusive
axes from 75 cm onto
no-cushioning vinyl tile surface
1
Specifications are subject to change without notice.