National Instruments NI 9264 Network Card User Manual


 
© National Instruments Corp. 13 NI 9264 Operating Instructions and Specifications
Power-down voltage .........................0 V
1
Output impedance.............................2.0 Ω
Accuracy
Stability
Gain drift ....................................6 ppm/°C
Offset drift..................................80 μV/°C
1
The power-down voltage peaks at 1.7 V, then exponentially discharges to 0 V in
200 ms. You can add a load to reduce peak voltage.
Measurement Conditions
Percent of
Reading
(Gain Error)
Percent of
Range
*
(Offset Error)
Calibrated, max (–40 to 70 °C) 0.15% 0.15%
Calibrated, typ (25 °C) 0.05% 0.05%
Uncalibrated, max (–40 to 70 °C) 0.6% 1.0%
Uncalibrated, typ (25 °C) 0.2% 0.25%
*
Range equals 10.5 V