National Instruments NI PMA-1115 Computer Monitor User Manual


 
NI PMA-1115 User Guide and Specifications 10 ni.com
Figure 8. Temperature/Humidity Relationship
Shock and Vibration
Operational shock ...................................10 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27.)
Random Vibration
Operating ................................................5 to 500 Hz, 0.31 g
rms
Nonoperating ..........................................5 to 500 Hz, 2.46 g
rms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Relative Humidity (%)
100
90
80
60
40
20
10
-20 0 10 20 30405060
Operation Range
Storage
Range
Storage
Range
Temper ature (°C)
Twb = 39 °C
T = 40 °C,
H = 90%
T = 50 °C,
H = 55%
T = 60 °C,
H = 39%