Chapter 2 Installation and Configuration
NI PXI-8108 User Manual 2-4 ni.com
Figure 2-2 shows an NI PXI-8108 installed in the system controller slot of
a National Instruments PXI-1042 chassis. You can place PXI devices in any
other slots.
Figure 2-2. NI PXI-8108 Controller Installed in a PXI Chassis
How to Remove the Controller from the PXI Chassis
The NI PXI-8108 controller is designed for easy handling. To remove the
unit from the PXI chassis, complete the following steps:
1. Power off the chassis.
2. Remove any cables that may be attached to the controller front panel.
3. Unscrew the bracket-retaining screws in the front panel. Refer to
Figure 2-1 for the location of these screws.
4. Press the injector/ejector handle down.
5. Slide the unit out of the chassis.
1 PXI-1042 Chassis 2 NI PXI-8108 Controller 3 Injector/Ejector Rail
1
2
3
NI PXI-1042