National Instruments NI-DAQ mx Base Computer Accessories User Manual


 
NI-DAQmx Base Getting Started Guide 14 ni.com
Tip You can view context help for the Task Configuration Utility by pressing <Ctrl-H>.
6. Click Save & Exit when you are finished configuring your tasks.
The task configuration is automatically saved into LabVIEW global
variables. You do not need to explicitly save the configuration.
To transfer the task configuration to other computers, click Export
Configuration and save the tasks to a file. You then can use Import
Configuration to import the task configuration.
Note The Import Configuration and Export Configuration options operate on the entire set
of tasks shown in the Task Configuration Utility. Importing a configuration replaces any
existing tasks, including the predefined tasks for the example programs.
Devices Using the LabVIEW 8.5 PDA Module for Windows Mobile
When you are using devices that use the LabVIEW 8.5 PDA Module for
Windows Mobile, the task configuration is built into the target application.
You cannot retrieve the task information after it is embedded in a built
application. Exporting the configuration allows you to preserve the task in
case of accidental deletion when using the Task Configuration Utility.