National Instruments PCI-8336 Switch User Manual


 
© National Instruments Corporation A-1 MXI-4 Series User Manual
A
Specifications
This appendix lists the system specifications for PCI MXI-4 and
PXI MXI-4 cards. These specifications are typical at 25 °C, unless
otherwise stated.
Physical
Dimensions
PCI ..................................................10.7 × 17.5 cm (4.2 × 6.9 in.)
PXI..................................................10.0 × 16.0 cm (3.9 × 6.3 in.)
Maximum cable lengths
Copper.............................................10 m
Fiber-optic....................................... 200 m
Slot requirements ...................................One slot (PCI or PXI)
Compatibility .........................................Fully compatible with the
PXI Hardware Specification,
Revision 2.1 and the
PCI Specification, Revision 2.2
Weight
PXI-8331..........................................25 Kg (.55 lb) typical
PCI-8331..........................................19 Kg (.42 lb) typical
PXI-8336..........................................25 Kg (.55 lb) typical
PCI-8336..........................................20 Kg (.44 lb) typical
PXI-8331 power requirement
3.3 V................................................<.21 A typical
5 V................................................... <1.4 A typical
PXI-8336 power requirement
3.3 V................................................<.34 A typical
5 V................................................... <1.4 A typical