NEC 2000 IPS Network Router User Manual


 
CHAPTER 3 MM0009/0304
Page 32
TERMINALS
Cell Station (CS)
Because of its small size, light weight and slenderness, the CS can be installed anywhere...the wall surface, the
ceiling or behind the ceiling. In addition, its expansion or relocation can be smoothly performed.
Followings are the specifications for the CS.
Specification of Cell Station
Table 3-4 2-Wired (U-Interface) Cell Station (CS) Specifications
Item Specifications
Radio Interface RCR STD-28 Ver. 2 (RF Power : 10mW Average)
PBX Interface 2-Wire (metallic)
Maximum Simultaneous Access per CS 3 Personal Stations
Volume Approx. 700 cc
Size
Approx. 141 (W) × 183 (D) × 36 (H) mm (Excluding Antenna)
Weight Approx. 380 g
Power Supply PBX Power Supply (DC-48V)
Local Power Supply (AC 100V/200V)
Application In Door Type
* This CS can download new soft program from MAT, so it can easily maintenance and operation.