ReadyNAS NVX Business Edition User Manual
Setting Up and Managing Your ReadyNAS NVX 2-29
v1.1, February 2009
1. Select the SNMP tab to display the SNMP settings.
2. Select the Enable SNMP service check box. You can leave the Community field set to
public, or specify a private name if you have opted for a more segregated monitoring scheme.
3. Enter a host name or an IP address in the Trap destination field. This is where all trap
messages will be sent. The following system events generate a trap:
• Abnormal power voltage
• Abnormal board enclosure temperature
•Fan failure
• UPS connected
• UPS detected power failure
• RAID disk sync started and finished
• RAID disk added, removed, and failure
• Snapshot invalidated
4. If you wish to limit SNMP access to only a secure list of hosts, specify the hosts in the Hosts
allowed access field.
5. Click Apply to save your settings.
When you have saved the SNMP settings on the ReadyNAS NVX Business Edition, you can
import the NETGEAR SNMP MIB to your SNMP client application. The NETGEAR MIB can be
obtained from the included Installation CD or downloaded from the NETGEAR Support site at
http://www.netgear.com/support.
SMTP
The ReadyNAS NVX Business Edition device has a built-in e-mail message transfer agent (MTA)
that is set up to send alert e-mail messages from the device. Some corporate environments,
however, might have a firewall that blocks untrusted MTAs from sending out messages.