Omega Speaker Systems CIO-RELAY16 Computer Hardware User Manual


 
2.2 Run InstaCal
TM
To run
InstaCal
TM
in the various forms of Windows, find the file named InstaCal.exe
using your file management system and double click your mouse on it. In DOS simply
type instacal and press the Enter key.
Once running,
InstaCal
TM
provides four sub-menus (plus exit).
1. Select
Install
(either highlight it and hit enter of double click your
mouse on it).
2. Select
Board #0
(select another number if Board #0 is already installed)
3. Select
Board Type
4. Move through the selections and highlight the particular board you
are installing (e.g. CIO-RELAY08 or CIO-RELAY16/M).
Either double click on the board or hit enter.
5. The board’s default settings are then displayed. The board’s defaults are:
BASE ADDRESS: 300H (768 Decimal)
WAIT STATE OFF
6. You are now ready to install the board in your computer. Open your PC (after
turning off the power) and install the board. After the board is installed and the
computer is closed up, turn the power back on.
7. Run
InstaCal
TM
again, and at the main menu select
Test.
a. Select the board you just installed
b. Select
Internal Test
c. The internal control registers of the board will then be tested. If this test
is successful, your board is installed correctly. If not, you likely have
a base address conflict, or have the base address switch set incorrectly.
Please refer to the next chapter for more information regarding selecting
and setting the base address.
d. If the
Internal Test
is completed successfully, you may want to check
that the I/O pins are working correctly. To check this select
External Test
and follow the instruction provided. This will
require the use of an ohmmeter.
3
6 SPECIFICATIONS
6.1 CIO-RELAY08, 16, 24 and 32 (standard versions)
POWER CONSUMPTION
+5V supply 510 mA typical plus 22 mA per active (on)
relay
GENERAL SPECIFICATIONS
Number 8, 16, 24, or 32
Contact arrangement Form C (SPDT)
Contact rating 3A @ 120V A.C or 28V D.C. resistive
Contact type Gold overlay silver
Contact resistance 100 milliohms max.
Operate time 20 milliseconds
Release time 10 milliseconds max.
Life expectancy 10 million mechanical operations min.
ENVIRONMENTAL
Vibration 10 to 55 Hz (Dual amplitude 1.5mm)
Shock 10G (11 milliseconds)
Dielectric isolation 500V (1 minute)
Life Expectancy 1 Million Operations Electrical
100,000 Operations @ Full Load
12