Omega WI8XX-U Scanner User Manual


 
72
GENERAL
Connection: Screw terminals
Line Voltage/Power: 90 to 240 Vac +/-10%, 50 to 400 Hz*;
110 to 375 Vdc, equivalent voltage; 5 W
* No CE compliance above 60 Hz
Low Voltage/Power Option:
20 to 36 Vdc or 24 Vac
**
+/-10%
; 4 W
External power source must meet Safety Agency
Approvals.
** Units can be powered safely with 24 Vac power
but, no Certification for CE are claimed.
External Fuse Required:
Time-Lag, IEC 127-3 recognized: 100 mA/250 V 400 mA/250 V
(Low Voltage/Power Option)
Time-Delay, UL 248-14 listed: 100 mA/250 V 400 mA/250 V
(Low Voltage/Power Option)
Environmental Conditions: 0 to 50°C (32 to 122°F), 90% RH non-condensing
Protection: NEMA-1/Type 1 front bezel
Dimensions: 48H x 96W x 127mm D (1.89 x 3.78 x 5")
Panel Cutout: 45H x 92mm W (1.772 x 3.622")
Weight: 353 g (0.78 lb)
Software: The software packages available for the
Temperature Wireless System products are
iConnect (configuration software for the Ethernet
interface), iLog (Excel-based software for
automatic data logging), and Mail Notifier (email
alarm notification software).
INTERFACE SPECIFICATIONS
Ethernet: Standards Compliance IEEE 802.3 10Base-T
(RJ45)
Supported Protocols: TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and
Telnet
LED Indicators: Network Activity, Network Link, Diagnostics,
Receive & Power
Management: Device configuration and monitoring through
embedded Web Server
Embedded Web Server: Serves WEB pages (Java™ Applets) containing
real-time data and live updated charts within
definable time intervals.
WIRELESS COMMUNICATION
Standard: DSSS; IEEE 802.15.4
Frequency 2.4 GHz (2410 MHz), Channel #12
Network Topology: Star Topology