Opticon 25-ULGPMU01-01 Scanner User Manual


 
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner
Redundant Decoding Settings
ZZ
Start/End
Program
Menu
[[
X0
No
redundancy
Y1
X1
Two times
redundant
Y2
%
X2
Three times
redundant
Y3
X3
Four times
redundant
Y!
Redundancy Settings - This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a
higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor
definition are used.
Positive and Negative Bar Codes
ZZ
Start/End
Program
Menu
[[
V2
Positive
bar codes
W3
V4
Both positive
and negative
bar codes
W5
%
Positive and Negative Bar Codes - Usually bar codes are printed black on white, but sometime white on black. These labels are
called positive and negative, respectively.
Page 57